Precautions for the use of microcomputer infusion pump
Release time:
2021-06-09 09:37
Source:
Www.csbeyond.com
1. It is recommended to use the consumables matched with the infusion pump. The infusion pump tube shall be used as required and replaced every day.
2. Select the infusion pump tube according to the nature of the infusion liquid and drug, such as the dark infusion pump tube.
3. When the infusion speed is less than 0.5 ml/h, a special infusion pump tube with anti-backflow function must be selected to prevent blood return from blocking the pipeline.
1. Install the infusion pump tube into the groove on the side of the handle panel.
2. Press down the handle of the stop clamp, install the pump tube into the groove, and then loosen it.
3. Install the pump tube into the groove in the middle of the air sensor through the peristaltic extrusion groove.
4. Close the pump door and open the pump pipe flow regulating clamp.
1. Press the [START/STOP] key to display STOP
2. Press the clear/confirm key, and when the horizontal line below the infusion speed flashes, press up and down to adjust the infusion speed.
3. Press the [Start/Stop] button to restart the infusion, indicating that the infusion is in progress. Note: decimal points and units
1. Infusion pump shell with slightly wet clean soft cloth to wipe.
2. The drip rate sensor is cleaned with absolute ethanol.
3. Disinfect regularly to prevent cross-infection. Wipe the instrument with 5% disinfectant, 2.25 glutaraldehyde or 75% alcohol.
Daily management of 5.
1. Start the infusion pump once a week to check the performance of the infusion pump, flow, capacity and blockage pressure test.
2. Avoid liquid infiltration into the pump; when the infusion pump is not in use, store it in a cool and dry place, avoid violent vibration, direct sunlight or ultraviolet radiation.
3. Special management, the establishment of the use of registration, regular inspection, maintenance and repair system.
1. Before using it for the first time, or not using it for a long time, when using it again, connect the infusion pump to the AC power source and charge the built-in battery for at least 12 hours.
2. When not in use for a long time, the internal battery shall be charged and discharged at least once a month; the working time of the battery shall be shortened after charging, and the new battery shall be replaced in time; the infusion pump shall be repaired in time if it fails.
Precautions, infusion, pump tube, infusion pump, 1.,2.,3., use, load, speed
24-hour service hotline: +86-400-066-7111
Address: Beyond Zone, Zhixian Rd, Xueshi Street, Yuelu District,410208, Changsha, China
Zip Code: 410208
Telephone : 0086-731-82564299
Mobile Phone:0086-19807315856
E-mail : sale@csbeyond.com
Copyright©2024 Hunan Biyang Medical Technology Co., Ltd. Supports: IPv6, IPv4